0000091 |
[Firmware] Ignition / Injection Scheduler |
minor |
always |
2008-12-22 21:55 |
2008-12-22 21:55 |
|
|
Reporter |
Fred |
View Status |
public |
|
|
Assigned To |
Fred |
|
Priority |
normal |
Resolution |
fixed |
|
|
Status |
closed |
|
Product Version |
|
|
|
Summary |
0000091: Logic that causes the injectors to stay hard not taking advance into account. |
|
Description |
The logic that causes the injectors to stay hard on is not taking advance into account. This is causing the step from requested pulsewidth to be "advance" large, so if pulse width increases from 10ms to 20ms and advance is 10ms, and the period of the whole cycle is 25ms, you will get a step from 15ms to 25ms/100% duty when the end of the pulse hits the point where the thing is scheduled from.
|
|
Additional Information |
|
| Tags |
No tags attached. |
|
|
Issue Type |
Bug |
|
|