Mantis Bug Tracker

View Issue Details Jump to Notes ] Print ]
IDProjectCategoryView StatusDate SubmittedLast Update
0000524FirmwareGeneral Featurespublic2012-02-12 03:522012-06-25 01:39
ReporterFred 
Assigned Topjohns30 
PrioritynormalSeverityminorReproducibilityN/A
StatusclosedResolutionfixed 
PlatformOSOS Version
Product Version0.2.0-SNAPSHOT 
Target Version0.2.0Fixed in Version0.2.0 
Summary0000524: Add Configurable Var Switch Feature
DescriptionSetup a GPIO function with configurable pin and configurable on/off Var value, to be expanded upon later. Have an array of X events with source variable (RPM, IAT, CHT, etc), and high/low trigger points.

Usable for temperature on fans, or VVT style RPM solenoids, etc.
TagsNo tags attached.
FirmwareVersion
Issue TypeNew Feature
Risk of Breakagevery low
Attached Files

- Relationships
has duplicate 0000541closedFred Add Configurable On/Off Outputs 
child of 0000518closedDeuceEFI Add GM DIS Decoder And/Or Required Logic 

-  Notes
User avatar (0001599)
Fred (administrator)
2012-06-23 14:06

Fixed in bf2ace064d95a9c787f725f11ebe41f96575b354 please test and close if you can use it to control your fan or whatever else :-) Default is K3 on at or above 5k rpm and off again below 4k rpm. K4 on at or above 100C and off again below 90C. Add your own to suit in the usual way.
User avatar (0001611)
pjohns30 (reporter)
2012-06-25 01:39

I only hooked it up to my scope, but it seems to be working just fine.


Copyright © 2000 - 2011 MantisBT Group