ID | Project | Category | View Status | Date Submitted | Last Update | ||||
0000483 | Firmware | Testing | public | 2011-12-20 19:54 | 2011-12-20 20:25 | ||||
Reporter | Fred | ||||||||
Assigned To | Fred | ||||||||
Priority | urgent | Severity | block | Reproducibility | N/A | ||||
Status | closed | Resolution | fixed | ||||||
Platform | OS | OS Version | |||||||
Product Version | 0.2.0-SNAPSHOT | ||||||||
Target Version | 0.2.0 | Fixed in Version | 0.2.0 | ||||||
Summary | 0000483: Add RPM Adjustable Bench Test Missing Tooth Hack | ||||||||
Description | Due to JimStims turning out to be hideously unreliable, unfixable, unupgradable, and generally of poor quality, I've decided to ditch using their stuff all together and write a quick and dirty missing tooth signal generator built right into FreeEMS. It should produce correct output with correct inverted behaviour and have a sync pulse on a second channel. It should use the existing MTX interface to avoid dealing with tanty-man and it should have dynamically settable RPM. It needs to have a usable RPM range from cranking through to redline or more for most patterns. Targeting 12-1, 24-1, 36-1 and 60-1 for the time being. | ||||||||
Additional Information | This work, and the fucked JimStim... is blocking development! | ||||||||
Tags | No tags attached. | ||||||||
FirmwareVersion | |||||||||
Issue Type | Bug | ||||||||
Risk of Breakage | low | ||||||||
Attached Files | |||||||||
![]() |
|
![]() Fred (administrator) 2011-12-20 20:25 |
Fixed in 75eb7331a5730d69883b95054d767eb5b3f6e5ba :-) Adios JimStim. |